Advantages
- Automatic speed stabilization
- Automatic frequency adjustment
- Automatic frequency search
- Synchronous output
- Speed preset
- Adjustable slow start
- High-precision automatic voltage stabilization
- Digital overheat protection
- Sensor self-adaptation
- Remote speed control
- DC control output
- Maximum output voltage setting
- Dual switch sensor full/empty shutdown
- Counting function
- 485 communication
Product Functions
Automatic Frequency Modulation: The controller automatically adjusts the output frequency in real-time, ensuring the feeder operates at the optimal frequency.
Automatic Speed Stabilization: The controller automatically adjusts voltage in real-time. Thus, it ensures consistent feeding speed, regardless of workpiece changes.
Fool-proof Automatic Frequency Search: This function quickly determines the optimal working frequency and other related parameters, simplifying user operation.
Automatic Voltage Stabilization: Even without automatic speed stabilization enabled, the controller eliminates feeding speed changes caused by power supply fluctuations and industrial frequency AC beat frequency effects.
Synchronous Output: This function synchronously locks the outputs of multiple controllers at the same frequency and phase, preventing beat frequency issues.
Full/Empty Material Shutdown: The controller provides a switch sensor signal input interface for full/empty material shutdown control with adjustable slow start time, open delay, close delay, logical direction setting, and other control functions.
Sensor Adaptation: Additionally, the controller adapts effortlessly to both NPN and PNP sensors, ensuring seamless compatibility and reliability.
Slow Start: Upon startup, the controller gradually increases the output voltage/feeding speed from 0 to the preset value, eliminating damage to vibration equipment from start-up shock.
Speed Preset: Users can directly select up to 4 preset output voltages through external control signals.
Acceleration Function: This function increases the maximum output voltage to 150% of the input voltage.
Maximum Output Voltage Setting: This setting allows users to define the maximum adjustable voltage, preventing accidental damage to vibration equipment by exceeding voltage limits.
Waveform Index: Users can adjust this parameter to balance controller efficiency and maximum power.
Remote Speed Control: The controller allows for direct control of output voltage or feeding speed using an external potentiometer, PLC, 1~5V voltage signal, or 4~20mA power signal.
24V DC Control Output: The controller provides a control signal through a transistor to directly control external devices like solenoid valves, coordinating with the controller.
Output Switch: A touch button on the panel allows users to instantly start/stop the machine, facilitating equipment debugging.
Keyboard Lock: Users can long-press the on/off button to lock all buttons, preventing accidental operation.
Parameter Password: Users can set a password to lock specific parameters, excluding output voltage/feeding speed, to prevent unauthorized changes.
Restore Factory Settings: This function allows users to quickly restore all adjusted parameters to factory defaults, setting the controller back to its original working state.
485 Communication: Various controller parameters can be adjusted remotely through 485 communication.
Technical Specification
| Item | Range | Unit | Description | ||
| Minimum | Typical | Maximum | |||
| Input voltage | 85 | 220 | 260 | V | AC effective value |
| Output voltage adjustment range | 0 | 260 | V | Less than 150% of input voltage | |
| Voltage adjustment accuracy | 1 | V | |||
| Voltage regulation accuracy | 0 | 10 | Vout/Vin | ||
| Voltage regulation response time | 0.0025 | 0.04 | s | One-tenth of the output voltage cycle | |
| Output current adjustment range | 0 | 10 | A | ||
| Output frequency | 25 | 400 | Hz | ||
| Frequency adjustment accuracy | 0.1 | Hz | |||
| Output waveform | sine | ||||
| Slow start time | 0 | 10 | s | Factory default 0.5 | |
| Delay time range | 0 | 20 | s | Factory default 0.2 | |
| Delay time accuracy | 0.1 | s | |||
| Overheat protection temperature | 60 | 65 | 65 | ℃ | |
| Analog control model | ModBus485 communication | V | Remote speed control voltage | ||
| Digital control signal | 24 | V | Switch signal control | ||
| Adjustment method | 6 | key | |||
| No-load power consumption | 3 | W | |||
| Display mode | 5 | digit | LED digital tube | ||
| Wage environment temperature | 0 | 25 | 40 | ℃ | No condensation |
| Wage environment humidity | 10 | 60 | 85 | % | |
Dimensions and Weight:
- Dimensions: 190mm long x 242mm wide x 94.5mm high
- Weight: 2670g (excluding accessories)