Features
Dimensions: L150mm*W69mm*H70mm90mm
Installation hole size: 130mm*62mm 3 years warranty
1. High power factor, saving electricity costs significantly. Compared to the ordinary controller as in the most commonly used 1.5A drive current, Suppose 1.0RMB per kilowatt, the use of this controller works eight hours a day can save about 1.6 RMB electricity.
2. High-performance intelligent photoelectric interface to connect an external photoelectric sensor (Radiation and reflection are available ), the machine built-in digital fuzzy recognition technology, in addition to the adaptive ambient light, the sensitivity can be set to 99 photoelectric, without costly fiber optic sensor, accurate identifying small or translucent feeding the workpiece.
3. Speed shuttle operation, patented design, fast and accurate, reliable and durable.
4. Optimization of external control connector, flexible and convenient installation.
5. Built-in intelligent slow start and slow stop program, ensure the start and stop moment feeding smoothly.
6. Output 24V 200mA DC power supply.
7. Adopts high-performance power devices, lowers heat loss, and optimizes thermal design, lowers temperature rise, works more stable and reliable.
8. High-precision regulator, In the case of the power grid voltage fluctuations, keeps the output voltage stable, and can effectively inhibit the beat effect caused by power frequency.
9. Customizable set the upper output voltage limit to meet various applications and machinery equipment required.
10. Highly integrated system, optimized dimensions, lightweight, small footprint, easy installation.
11. Fully enclosed housing, adapted to the hostile working environment.
12. With overheating, overload, output short circuit protection.
Technical Specification
Item | Range value | Unit | Remark | |
Min. | Max. | |||
Input voltage | 85 | 265 | V | Sine wave50/60Hz |
Output voltage | 0 | 250 | V | Voltage Regulation Accurecy: 1v |
Output current | 0 | 4.5 | A | Power rating: 1.5A/3a/4.5A |
Output frequency | 40 | 400 | Hz | Frequencyrange accuracy: 0.1Hz |
Output wave | Sine wave | |||
Start delay time range | 0 | 30 | S | Delay time accuracy: 15 |
Off delay time range | 0 | 30 | S | Delay time accuracy: 15 |
Slow start time | 0.1 | 9.9 | S | Slow start time: 0.15 |
Slow stop time | 0.1 | 0.3 | S | Program automaticcontrol |
Photoelectric sensitivity | 0 | 99 | The higher the value. The greater the sensitiviry | |
Dc control output | 24V 200mA | Drives external sensors and low-power solenoid valves for power supply | ||
No-load power consumption | <3W | W | Input voltage: 220V 50Hz | |
Display mode | LED+Indicator light 5 | |||
Operation mode | Keys+ coding switch | Speed shuttle operation, patented design | ||
Control mode | With infrared photoelctric sensoer | Material full/ empty materialshutdown control | ||
Low level signal (NPN general purpose sensor or PLC) | ||||
Working temperature | -20 | 40 | ℃ | Overheating protection:58℃ |
Working relative humidity | 0 | 90 | % | No-condensate |
Protection measures | Overheating, over current, output short circuit protection | |||
Application | Electromagnetic |